[{"data":1,"prerenderedAt":1114},["ShallowReactive",2],{"mdc-3lvpvg-key":3},{"data":4,"body":5},{},{"type":6,"children":7},"root",[8,17,36,40,47,59,92,104,111,168,173,206,209,215,221,226,253,259,382,394,397,403,415,420,438,449,482,487,490,496,508,513,544,549,552,558,563,576,593,598,616,619,625,637,675,685,688,694,699,757,767,770,776,781,799,804,822,825,831,837,842,848,853,859,864,870,875,885,888,894,899,905,938,943,946,952,975,980,983,989,994,1002,1007,1025,1030,1033,1039,1057,1067,1070,1076],{"type":9,"tag":10,"props":11,"children":13},"element","h1",{"id":12},"transmission-electron-microscopy-tem-detailed-summary",[14],{"type":15,"value":16},"text","🔬 Transmission Electron Microscopy (TEM) — Detailed Summary",{"type":9,"tag":18,"props":19,"children":20},"p",{},[21,23,29,31],{"type":15,"value":22},"This lecture explains ",{"type":9,"tag":24,"props":25,"children":26},"strong",{},[27],{"type":15,"value":28},"how electron microscopes work",{"type":15,"value":30},", why they are powerful for structural biology, how they compare to light microscopes, and what technological breakthroughs enabled the modern ",{"type":9,"tag":24,"props":32,"children":33},{},[34],{"type":15,"value":35},"“resolution revolution” in cryo-EM.",{"type":9,"tag":37,"props":38,"children":39},"hr",{},[],{"type":9,"tag":41,"props":42,"children":44},"h2",{"id":43},"️-1-basic-principle-of-the-electron-microscope",[45],{"type":15,"value":46},"⚙️ 1. Basic Principle of the Electron Microscope",{"type":9,"tag":18,"props":48,"children":49},{},[50,52,57],{"type":15,"value":51},"There are ",{"type":9,"tag":24,"props":53,"children":54},{},[55],{"type":15,"value":56},"two main types of electron microscopes",{"type":15,"value":58},":",{"type":9,"tag":60,"props":61,"children":62},"ul",{},[63,74],{"type":9,"tag":64,"props":65,"children":66},"li",{},[67,72],{"type":9,"tag":24,"props":68,"children":69},{},[70],{"type":15,"value":71},"Scanning Electron Microscope (SEM)",{"type":15,"value":73}," → scans the surface",{"type":9,"tag":64,"props":75,"children":76},{},[77,82,84,90],{"type":9,"tag":24,"props":78,"children":79},{},[80],{"type":15,"value":81},"Transmission Electron Microscope (TEM)",{"type":15,"value":83}," → electrons pass ",{"type":9,"tag":85,"props":86,"children":87},"em",{},[88],{"type":15,"value":89},"through",{"type":15,"value":91}," the sample",{"type":9,"tag":18,"props":93,"children":94},{},[95,97,102],{"type":15,"value":96},"👉 For ",{"type":9,"tag":24,"props":98,"children":99},{},[100],{"type":15,"value":101},"high-resolution structural biology",{"type":15,"value":103},", TEM is used because the transmitted electrons can form detailed images of internal structure.",{"type":9,"tag":105,"props":106,"children":108},"h3",{"id":107},"how-tem-works-step-by-step",[109],{"type":15,"value":110},"🧠 How TEM Works — Step by Step",{"type":9,"tag":112,"props":113,"children":114},"ol",{},[115,125,130,140,145,153,158],{"type":9,"tag":64,"props":116,"children":117},{},[118,123],{"type":9,"tag":24,"props":119,"children":120},{},[121],{"type":15,"value":122},"Electron gun",{"type":15,"value":124}," emits electrons",{"type":9,"tag":64,"props":126,"children":127},{},[128],{"type":15,"value":129},"High voltage (~300 kV) accelerates electrons",{"type":9,"tag":64,"props":131,"children":132},{},[133,138],{"type":9,"tag":24,"props":134,"children":135},{},[136],{"type":15,"value":137},"Electromagnetic lenses",{"type":15,"value":139}," focus the beam",{"type":9,"tag":64,"props":141,"children":142},{},[143],{"type":15,"value":144},"Beam passes through the specimen",{"type":9,"tag":64,"props":146,"children":147},{},[148],{"type":9,"tag":24,"props":149,"children":150},{},[151],{"type":15,"value":152},"Scattered electrons form an image",{"type":9,"tag":64,"props":154,"children":155},{},[156],{"type":15,"value":157},"Image is magnified by additional lenses",{"type":9,"tag":64,"props":159,"children":160},{},[161,163],{"type":15,"value":162},"Recorded on a ",{"type":9,"tag":24,"props":164,"children":165},{},[166],{"type":15,"value":167},"fluorescent screen or digital camera",{"type":9,"tag":18,"props":169,"children":170},{},[171],{"type":15,"value":172},"Key lens systems:",{"type":9,"tag":60,"props":174,"children":175},{},[176,186,196],{"type":9,"tag":64,"props":177,"children":178},{},[179,184],{"type":9,"tag":24,"props":180,"children":181},{},[182],{"type":15,"value":183},"Condenser lenses",{"type":15,"value":185}," → focus beam on sample",{"type":9,"tag":64,"props":187,"children":188},{},[189,194],{"type":9,"tag":24,"props":190,"children":191},{},[192],{"type":15,"value":193},"Objective lens",{"type":15,"value":195}," → forms first image",{"type":9,"tag":64,"props":197,"children":198},{},[199,204],{"type":9,"tag":24,"props":200,"children":201},{},[202],{"type":15,"value":203},"Intermediate + projection lenses",{"type":15,"value":205}," → further magnification",{"type":9,"tag":37,"props":207,"children":208},{},[],{"type":9,"tag":41,"props":210,"children":212},{"id":211},"_2-comparison-light-microscope-vs-electron-microscope",[213],{"type":15,"value":214},"🔍 2. Comparison: Light Microscope vs Electron Microscope",{"type":9,"tag":105,"props":216,"children":218},{"id":217},"similarities",[219],{"type":15,"value":220},"✅ Similarities",{"type":9,"tag":18,"props":222,"children":223},{},[224],{"type":15,"value":225},"Both have:",{"type":9,"tag":60,"props":227,"children":228},{},[229,234,239,244,248],{"type":9,"tag":64,"props":230,"children":231},{},[232],{"type":15,"value":233},"Illumination system",{"type":9,"tag":64,"props":235,"children":236},{},[237],{"type":15,"value":238},"Condenser lens",{"type":9,"tag":64,"props":240,"children":241},{},[242],{"type":15,"value":243},"Specimen holder",{"type":9,"tag":64,"props":245,"children":246},{},[247],{"type":15,"value":193},{"type":9,"tag":64,"props":249,"children":250},{},[251],{"type":15,"value":252},"Imaging/detection system",{"type":9,"tag":105,"props":254,"children":256},{"id":255},"important-differences",[257],{"type":15,"value":258},"❗ Important Differences",{"type":9,"tag":260,"props":261,"children":262},"table",{},[263,287],{"type":9,"tag":264,"props":265,"children":266},"thead",{},[267],{"type":9,"tag":268,"props":269,"children":270},"tr",{},[271,277,282],{"type":9,"tag":272,"props":273,"children":274},"th",{},[275],{"type":15,"value":276},"Feature",{"type":9,"tag":272,"props":278,"children":279},{},[280],{"type":15,"value":281},"Light Microscopy",{"type":9,"tag":272,"props":283,"children":284},{},[285],{"type":15,"value":286},"Electron Microscopy",{"type":9,"tag":288,"props":289,"children":290},"tbody",{},[291,310,328,346,364],{"type":9,"tag":268,"props":292,"children":293},{},[294,300,305],{"type":9,"tag":295,"props":296,"children":297},"td",{},[298],{"type":15,"value":299},"Lenses",{"type":9,"tag":295,"props":301,"children":302},{},[303],{"type":15,"value":304},"Glass lenses (fixed focal length)",{"type":9,"tag":295,"props":306,"children":307},{},[308],{"type":15,"value":309},"Electromagnetic lenses (focal length adjustable via current)",{"type":9,"tag":268,"props":311,"children":312},{},[313,318,323],{"type":9,"tag":295,"props":314,"children":315},{},[316],{"type":15,"value":317},"Depth of field",{"type":9,"tag":295,"props":319,"children":320},{},[321],{"type":15,"value":322},"Small",{"type":9,"tag":295,"props":324,"children":325},{},[326],{"type":15,"value":327},"Large",{"type":9,"tag":268,"props":329,"children":330},{},[331,336,341],{"type":9,"tag":295,"props":332,"children":333},{},[334],{"type":15,"value":335},"Environment",{"type":9,"tag":295,"props":337,"children":338},{},[339],{"type":15,"value":340},"Air",{"type":9,"tag":295,"props":342,"children":343},{},[344],{"type":15,"value":345},"Ultra-high vacuum",{"type":9,"tag":268,"props":347,"children":348},{},[349,354,359],{"type":9,"tag":295,"props":350,"children":351},{},[352],{"type":15,"value":353},"Sample prep",{"type":9,"tag":295,"props":355,"children":356},{},[357],{"type":15,"value":358},"Simple",{"type":9,"tag":295,"props":360,"children":361},{},[362],{"type":15,"value":363},"Must be fixed / vitrified",{"type":9,"tag":268,"props":365,"children":366},{},[367,372,377],{"type":9,"tag":295,"props":368,"children":369},{},[370],{"type":15,"value":371},"Resolution limit",{"type":9,"tag":295,"props":373,"children":374},{},[375],{"type":15,"value":376},"Limited by light wavelength",{"type":9,"tag":295,"props":378,"children":379},{},[380],{"type":15,"value":381},"Limited by radiation damage & contrast",{"type":9,"tag":18,"props":383,"children":384},{},[385,387,392],{"type":15,"value":386},"In EM, changing lens current → ",{"type":9,"tag":24,"props":388,"children":389},{},[390],{"type":15,"value":391},"changes focal length and magnification continuously",{"type":15,"value":393}," (very flexible).",{"type":9,"tag":37,"props":395,"children":396},{},[],{"type":9,"tag":41,"props":398,"children":400},{"id":399},"️-3-why-samples-must-be-frozen-cryo-em-concept",[401],{"type":15,"value":402},"❄️ 3. Why Samples Must Be Frozen (Cryo-EM Concept)",{"type":9,"tag":18,"props":404,"children":405},{},[406,408,413],{"type":15,"value":407},"TEM requires ",{"type":9,"tag":24,"props":409,"children":410},{},[411],{"type":15,"value":412},"ultra-high vacuum",{"type":15,"value":414}," — otherwise electrons scatter and the beam becomes unstable.",{"type":9,"tag":18,"props":416,"children":417},{},[418],{"type":15,"value":419},"But vacuum causes:",{"type":9,"tag":60,"props":421,"children":422},{},[423,433],{"type":9,"tag":64,"props":424,"children":425},{},[426,428],{"type":15,"value":427},"Liquid samples to ",{"type":9,"tag":24,"props":429,"children":430},{},[431],{"type":15,"value":432},"evaporate instantly",{"type":9,"tag":64,"props":434,"children":435},{},[436],{"type":15,"value":437},"Biological structures to collapse",{"type":9,"tag":105,"props":439,"children":441},{"id":440},"solution-vitrified-ice",[442,444],{"type":15,"value":443},"Solution → ",{"type":9,"tag":24,"props":445,"children":446},{},[447],{"type":15,"value":448},"Vitrified ice",{"type":9,"tag":60,"props":450,"children":451},{},[452,457,467,472],{"type":9,"tag":64,"props":453,"children":454},{},[455],{"type":15,"value":456},"Sample is rapidly frozen",{"type":9,"tag":64,"props":458,"children":459},{},[460,462],{"type":15,"value":461},"Water forms ",{"type":9,"tag":24,"props":463,"children":464},{},[465],{"type":15,"value":466},"amorphous (vitreous) ice",{"type":9,"tag":64,"props":468,"children":469},{},[470],{"type":15,"value":471},"Maintains native molecular structure",{"type":9,"tag":64,"props":473,"children":474},{},[475,477],{"type":15,"value":476},"Stable at ",{"type":9,"tag":24,"props":478,"children":479},{},[480],{"type":15,"value":481},"liquid nitrogen temperature",{"type":9,"tag":18,"props":483,"children":484},{},[485],{"type":15,"value":486},"This allows proteins and complexes to be imaged without dehydration artifacts.",{"type":9,"tag":37,"props":488,"children":489},{},[],{"type":9,"tag":41,"props":491,"children":493},{"id":492},"️-4-radiation-damage-a-fundamental-limitation",[494],{"type":15,"value":495},"☢️ 4. Radiation Damage — A Fundamental Limitation",{"type":9,"tag":18,"props":497,"children":498},{},[499,501,506],{"type":15,"value":500},"Electron beams ",{"type":9,"tag":24,"props":502,"children":503},{},[504],{"type":15,"value":505},"destroy biological samples",{"type":15,"value":507},".",{"type":9,"tag":18,"props":509,"children":510},{},[511],{"type":15,"value":512},"Therefore:",{"type":9,"tag":60,"props":514,"children":515},{},[516,526],{"type":9,"tag":64,"props":517,"children":518},{},[519,521],{"type":15,"value":520},"Must use ",{"type":9,"tag":24,"props":522,"children":523},{},[524],{"type":15,"value":525},"low electron dose",{"type":9,"tag":64,"props":527,"children":528},{},[529,531],{"type":15,"value":530},"Trade-off:",{"type":9,"tag":60,"props":532,"children":533},{},[534,539],{"type":9,"tag":64,"props":535,"children":536},{},[537],{"type":15,"value":538},"Low dose → low signal & contrast",{"type":9,"tag":64,"props":540,"children":541},{},[542],{"type":15,"value":543},"High dose → high resolution but sample destruction",{"type":9,"tag":18,"props":545,"children":546},{},[547],{"type":15,"value":548},"This balance is one of the central challenges in cryo-EM.",{"type":9,"tag":37,"props":550,"children":551},{},[],{"type":9,"tag":41,"props":553,"children":555},{"id":554},"_5-resolution-why-electrons-are-powerful",[556],{"type":15,"value":557},"📏 5. Resolution — Why Electrons Are Powerful",{"type":9,"tag":18,"props":559,"children":560},{},[561],{"type":15,"value":562},"Resolution depends on wavelength:",{"type":9,"tag":60,"props":564,"children":565},{},[566,571],{"type":9,"tag":64,"props":567,"children":568},{},[569],{"type":15,"value":570},"Visible light → ~400–700 nm",{"type":9,"tag":64,"props":572,"children":573},{},[574],{"type":15,"value":575},"Electrons (300 kV) → ~2 picometers",{"type":9,"tag":18,"props":577,"children":578},{},[579,581,586,588],{"type":15,"value":580},"This is ",{"type":9,"tag":24,"props":582,"children":583},{},[584],{"type":15,"value":585},"orders of magnitude smaller",{"type":15,"value":587},", meaning ",{"type":9,"tag":24,"props":589,"children":590},{},[591],{"type":15,"value":592},"angstrom-level resolution is theoretically possible.",{"type":9,"tag":18,"props":594,"children":595},{},[596],{"type":15,"value":597},"However in biology, practical limits come from:",{"type":9,"tag":60,"props":599,"children":600},{},[601,606,611],{"type":9,"tag":64,"props":602,"children":603},{},[604],{"type":15,"value":605},"Radiation damage",{"type":9,"tag":64,"props":607,"children":608},{},[609],{"type":15,"value":610},"Poor contrast",{"type":9,"tag":64,"props":612,"children":613},{},[614],{"type":15,"value":615},"Beam-induced motion",{"type":9,"tag":37,"props":617,"children":618},{},[],{"type":9,"tag":41,"props":620,"children":622},{"id":621},"_6-object-size-range-observable-by-em",[623],{"type":15,"value":624},"🧬 6. Object Size Range Observable by EM",{"type":9,"tag":18,"props":626,"children":627},{},[628,630,635],{"type":15,"value":629},"Electron microscopy spans a ",{"type":9,"tag":24,"props":631,"children":632},{},[633],{"type":15,"value":634},"huge size range",{"type":15,"value":636},", for example:",{"type":9,"tag":60,"props":638,"children":639},{},[640,645,650,655,660,665,670],{"type":9,"tag":64,"props":641,"children":642},{},[643],{"type":15,"value":644},"Cells → micrometers",{"type":9,"tag":64,"props":646,"children":647},{},[648],{"type":15,"value":649},"Bacteria (~E. coli) → few µm",{"type":9,"tag":64,"props":651,"children":652},{},[653],{"type":15,"value":654},"Viruses → ~50 nm",{"type":9,"tag":64,"props":656,"children":657},{},[658],{"type":15,"value":659},"Proteins → ~10–15 nm",{"type":9,"tag":64,"props":661,"children":662},{},[663],{"type":15,"value":664},"α-helices → ~3 nm",{"type":9,"tag":64,"props":666,"children":667},{},[668],{"type":15,"value":669},"Amino acids → ~5 Å",{"type":9,"tag":64,"props":671,"children":672},{},[673],{"type":15,"value":674},"Atoms → ~1 Å",{"type":9,"tag":18,"props":676,"children":677},{},[678,680],{"type":15,"value":679},"Thus TEM can bridge ",{"type":9,"tag":24,"props":681,"children":682},{},[683],{"type":15,"value":684},"cell biology → molecular → atomic structure.",{"type":9,"tag":37,"props":686,"children":687},{},[],{"type":9,"tag":41,"props":689,"children":691},{"id":690},"_7-historical-development-of-electron-microscopy",[692],{"type":15,"value":693},"📚 7. Historical Development of Electron Microscopy",{"type":9,"tag":18,"props":695,"children":696},{},[697],{"type":15,"value":698},"Key milestones:",{"type":9,"tag":60,"props":700,"children":701},{},[702,712,722,732,742,747,752],{"type":9,"tag":64,"props":703,"children":704},{},[705,710],{"type":9,"tag":24,"props":706,"children":707},{},[708],{"type":15,"value":709},"1897 — Thomson",{"type":15,"value":711}," discovers electron",{"type":9,"tag":64,"props":713,"children":714},{},[715,720],{"type":9,"tag":24,"props":716,"children":717},{},[718],{"type":15,"value":719},"1920s — de Broglie",{"type":15,"value":721}," proposes wave nature of electrons",{"type":9,"tag":64,"props":723,"children":724},{},[725,730],{"type":9,"tag":24,"props":726,"children":727},{},[728],{"type":15,"value":729},"1926 — Busch",{"type":15,"value":731}," shows magnetic/electric fields can act as lenses",{"type":9,"tag":64,"props":733,"children":734},{},[735,740],{"type":9,"tag":24,"props":736,"children":737},{},[738],{"type":15,"value":739},"1929 — Ruska",{"type":15,"value":741}," develops magnetic lens systems",{"type":9,"tag":64,"props":743,"children":744},{},[745],{"type":15,"value":746},"First TEM prototype built",{"type":9,"tag":64,"props":748,"children":749},{},[750],{"type":15,"value":751},"Rapid improvements → resolution surpasses light microscopy",{"type":9,"tag":64,"props":753,"children":754},{},[755],{"type":15,"value":756},"Commercial TEM produced by Siemens",{"type":9,"tag":18,"props":758,"children":759},{},[760,762],{"type":15,"value":761},"Modern designs still use many principles invented in the ",{"type":9,"tag":24,"props":763,"children":764},{},[765],{"type":15,"value":766},"1920–30s.",{"type":9,"tag":37,"props":768,"children":769},{},[],{"type":9,"tag":41,"props":771,"children":773},{"id":772},"_8-modern-tem-instruments-and-cost",[774],{"type":15,"value":775},"💰 8. Modern TEM Instruments and Cost",{"type":9,"tag":18,"props":777,"children":778},{},[779],{"type":15,"value":780},"Typical accelerating voltages:",{"type":9,"tag":60,"props":782,"children":783},{},[784,789,794],{"type":9,"tag":64,"props":785,"children":786},{},[787],{"type":15,"value":788},"120 kV → smaller and cheaper (~2–3 million DKK)",{"type":9,"tag":64,"props":790,"children":791},{},[792],{"type":15,"value":793},"200 kV → mid-range",{"type":9,"tag":64,"props":795,"children":796},{},[797],{"type":15,"value":798},"300 kV → large high-end instruments (~40–50 million DKK)",{"type":9,"tag":18,"props":800,"children":801},{},[802],{"type":15,"value":803},"Higher voltage:",{"type":9,"tag":60,"props":805,"children":806},{},[807,812,817],{"type":9,"tag":64,"props":808,"children":809},{},[810],{"type":15,"value":811},"Better penetration",{"type":9,"tag":64,"props":813,"children":814},{},[815],{"type":15,"value":816},"Higher resolution potential",{"type":9,"tag":64,"props":818,"children":819},{},[820],{"type":15,"value":821},"Much higher cost and size",{"type":9,"tag":37,"props":823,"children":824},{},[],{"type":9,"tag":41,"props":826,"children":828},{"id":827},"️-9-why-use-electrons-vs-x-rays-vs-light-vs-neutrons",[829],{"type":15,"value":830},"⚛️ 9. Why Use Electrons vs X-rays vs Light vs Neutrons",{"type":9,"tag":105,"props":832,"children":834},{"id":833},"visible-light",[835],{"type":15,"value":836},"🌈 Visible Light",{"type":9,"tag":18,"props":838,"children":839},{},[840],{"type":15,"value":841},"✔ Non-damaging\n✔ Easy to focus\n❌ Low resolution",{"type":9,"tag":105,"props":843,"children":845},{"id":844},"️-x-rays",[846],{"type":15,"value":847},"☢️ X-rays",{"type":9,"tag":18,"props":849,"children":850},{},[851],{"type":15,"value":852},"✔ Atomic wavelength\n✔ Good penetration\n❌ Hard to focus (need diffraction + math reconstruction)\n❌ Radiation damage",{"type":9,"tag":105,"props":854,"children":856},{"id":855},"electrons",[857],{"type":15,"value":858},"⚡ Electrons",{"type":9,"tag":18,"props":860,"children":861},{},[862],{"type":15,"value":863},"✔ Even smaller wavelength\n✔ Can be focused with magnetic lenses\n❌ Poor penetration → sample must be very thin (\u003C100 nm ideal ~30 nm)\n❌ Radiation damage",{"type":9,"tag":105,"props":865,"children":867},{"id":866},"neutrons",[868],{"type":15,"value":869},"🧊 Neutrons",{"type":9,"tag":18,"props":871,"children":872},{},[873],{"type":15,"value":874},"✔ Very low damage\n✔ Small wavelength\n❌ Hard to produce\n❌ Few facilities",{"type":9,"tag":18,"props":876,"children":877},{},[878,880],{"type":15,"value":879},"Example: ",{"type":9,"tag":24,"props":881,"children":882},{},[883],{"type":15,"value":884},"ESS neutron source in Sweden.",{"type":9,"tag":37,"props":886,"children":887},{},[],{"type":9,"tag":41,"props":889,"children":891},{"id":890},"_10-the-cryo-em-resolution-revolution-2013",[892],{"type":15,"value":893},"🚀 10. The Cryo-EM “Resolution Revolution” (≈2013)",{"type":9,"tag":18,"props":895,"children":896},{},[897],{"type":15,"value":898},"Major breakthroughs:",{"type":9,"tag":105,"props":900,"children":902},{"id":901},"direct-electron-detectors",[903],{"type":15,"value":904},"🎥 Direct Electron Detectors",{"type":9,"tag":60,"props":906,"children":907},{},[908,913,923,933],{"type":9,"tag":64,"props":909,"children":910},{},[911],{"type":15,"value":912},"Ultra-fast, ultra-sensitive cameras",{"type":9,"tag":64,"props":914,"children":915},{},[916,918],{"type":15,"value":917},"Record ",{"type":9,"tag":24,"props":919,"children":920},{},[921],{"type":15,"value":922},"movies instead of single exposures",{"type":9,"tag":64,"props":924,"children":925},{},[926,928],{"type":15,"value":927},"Allows correction of ",{"type":9,"tag":24,"props":929,"children":930},{},[931],{"type":15,"value":932},"beam-induced motion",{"type":9,"tag":64,"props":934,"children":935},{},[936],{"type":15,"value":937},"Frames can be aligned → sharper image",{"type":9,"tag":18,"props":939,"children":940},{},[941],{"type":15,"value":942},"Huge improvement in resolution.",{"type":9,"tag":37,"props":944,"children":945},{},[],{"type":9,"tag":105,"props":947,"children":949},{"id":948},"phase-plates",[950],{"type":15,"value":951},"🌊 Phase Plates",{"type":9,"tag":60,"props":953,"children":954},{},[955,965,970],{"type":9,"tag":64,"props":956,"children":957},{},[958,960],{"type":15,"value":959},"Increase ",{"type":9,"tag":24,"props":961,"children":962},{},[963],{"type":15,"value":964},"phase contrast",{"type":9,"tag":64,"props":966,"children":967},{},[968],{"type":15,"value":969},"Makes weakly scattering biological particles easier to see",{"type":9,"tag":64,"props":971,"children":972},{},[973],{"type":15,"value":974},"Improves signal without increasing radiation dose",{"type":9,"tag":18,"props":976,"children":977},{},[978],{"type":15,"value":979},"Essential for visualizing proteins.",{"type":9,"tag":37,"props":981,"children":982},{},[],{"type":9,"tag":105,"props":984,"children":986},{"id":985},"spherical-aberration-cs-correctors",[987],{"type":15,"value":988},"🔧 Spherical Aberration (Cs) Correctors",{"type":9,"tag":18,"props":990,"children":991},{},[992],{"type":15,"value":993},"Problem:",{"type":9,"tag":60,"props":995,"children":996},{},[997],{"type":9,"tag":64,"props":998,"children":999},{},[1000],{"type":15,"value":1001},"Objective lens imperfections cause electrons to focus incorrectly",{"type":9,"tag":18,"props":1003,"children":1004},{},[1005],{"type":15,"value":1006},"Solution:",{"type":9,"tag":60,"props":1008,"children":1009},{},[1010,1020],{"type":9,"tag":64,"props":1011,"children":1012},{},[1013,1015],{"type":15,"value":1014},"Add ",{"type":9,"tag":24,"props":1016,"children":1017},{},[1018],{"type":15,"value":1019},"quadrupole/hexapole correctors",{"type":9,"tag":64,"props":1021,"children":1022},{},[1023],{"type":15,"value":1024},"Sharpen image quality",{"type":9,"tag":18,"props":1026,"children":1027},{},[1028],{"type":15,"value":1029},"Major contribution to high-resolution cryo-EM.",{"type":9,"tag":37,"props":1031,"children":1032},{},[],{"type":9,"tag":105,"props":1034,"children":1036},{"id":1035},"advanced-image-processing",[1037],{"type":15,"value":1038},"💻 Advanced Image Processing",{"type":9,"tag":60,"props":1040,"children":1041},{},[1042,1047,1052],{"type":9,"tag":64,"props":1043,"children":1044},{},[1045],{"type":15,"value":1046},"Powerful computational algorithms",{"type":9,"tag":64,"props":1048,"children":1049},{},[1050],{"type":15,"value":1051},"Automation of data collection",{"type":9,"tag":64,"props":1053,"children":1054},{},[1055],{"type":15,"value":1056},"Single-particle reconstruction",{"type":9,"tag":18,"props":1058,"children":1059},{},[1060,1062],{"type":15,"value":1061},"These allowed routine ",{"type":9,"tag":24,"props":1063,"children":1064},{},[1065],{"type":15,"value":1066},"near-atomic structures of proteins.",{"type":9,"tag":37,"props":1068,"children":1069},{},[],{"type":9,"tag":10,"props":1071,"children":1073},{"id":1072},"key-take-home-messages",[1074],{"type":15,"value":1075},"🧠 Key Take-Home Messages",{"type":9,"tag":18,"props":1077,"children":1078},{},[1079,1081,1086,1088,1093,1095,1100,1102,1107,1109],{"type":15,"value":1080},"⭐ TEM enables ",{"type":9,"tag":24,"props":1082,"children":1083},{},[1084],{"type":15,"value":1085},"atomic-level structural biology",{"type":15,"value":1087},"\n⭐ Resolution is limited by ",{"type":9,"tag":24,"props":1089,"children":1090},{},[1091],{"type":15,"value":1092},"radiation damage + contrast",{"type":15,"value":1094},", not wavelength\n⭐ Samples must be ",{"type":9,"tag":24,"props":1096,"children":1097},{},[1098],{"type":15,"value":1099},"vitrified and extremely thin",{"type":15,"value":1101},"\n⭐ Cryo-EM revolution came from ",{"type":9,"tag":24,"props":1103,"children":1104},{},[1105],{"type":15,"value":1106},"detectors + computation + aberration correction",{"type":15,"value":1108},"\n⭐ Electrons can be focused → unlike X-rays\n⭐ Cryo-EM bridges the gap between ",{"type":9,"tag":24,"props":1110,"children":1111},{},[1112],{"type":15,"value":1113},"cell biology and atomic structure",1775084310980]